At a Glance
Four facts to hold on to.
BOD measures
Oxygen microbes use to break down waste.
Standard test
5 days at 20°C.
CPCB Class A
BOD 2 mg/L or less, DO 6 mg/L or more.
BOD vs COD
Different tests. COD is usually higher.
In this lesson
What BOD Actually Measures
What BOD measures
- Sewage and food scraps contain organic matter.
- Bacteria use oxygen as they break it down.
- BOD estimates that oxygen demand in a water sample.
- It helps assess organic pollution in rivers and wastewater.
- It does not measure oxygen in blood or air.
- Dissolved oxygen (DO) is oxygen in the water now. BOD is oxygen microbes may use during the test. They are different readings.
Follow the oxygen through a river
- A drain releases untreated sewage.
- Microbes feed on its organic matter.
- Their activity uses dissolved oxygen.
- Fish may then struggle to breathe.
- More biodegradable waste often raises BOD.
- A single BOD result cannot prove a river is safe or unsafe. Flow, temperature, sunlight and fresh oxygen also matter.
- High BOD is a warning of oxygen pressure. It is not a direct measure of poison, germs or every pollutant.
True or False: Biological Oxygen Demand is a standard criterion for pollution assay in aquatic ecosystems.
How BOD Is Measured, and What Counts as Clean
How the five-day test works
- A laboratory measures dissolved oxygen in a prepared sample. It may dilute or seed the sample.
- The sealed sample stays at 20°C in the dark for five days.
- The laboratory measures dissolved oxygen again. The fall gives five-day BOD.
- A result of 6 mg/L means microbes used oxygen equal to 6 milligrams per litre during the test.
- It does not say the river held 6 mg/L of oxygen when sampled.
- Compare results only if the same standard method was used.
- Source: USGS five-day BOD method.
India’s water-use classes
- The Central Pollution Control Board (CPCB) sets designated-best-use criteria.
- A class describes a water use and several needed conditions. BOD alone does not assign a class.
| Class | Designated use | BOD limit | Minimum DO |
|---|---|---|---|
| A | Drinking source after disinfection | 2 mg/L | 6 mg/L |
| B | Outdoor bathing | 3 mg/L | 5 mg/L |
| C | Drinking source after conventional treatment and disinfection | 3 mg/L | 4 mg/L |
| D | Wildlife and fisheries | No BOD limit listed | 4 mg/L |
| E | Irrigation, industrial cooling or controlled waste disposal | No BOD limit listed | No DO limit listed |
- Classes also use other tests, such as bacteria, pH or ammonia.
- Class E is a use category, not a declaration that water is clean.
- Source: CPCB designated-best-use criteria.
A treatment-plant example
- A town’s sewage enters a plant at 180 mg/L BOD. Treated outflow measures 30 mg/L.
- The measured BOD fell by 150 mg/L, or about 83%.
- This shows treatment can reduce biodegradable waste. It does not prove the discharge meets a legal limit.
- River water then mixes with the outflow. Never treat a wastewater result as a river classification.
True or False: CPCB’s Class A water, the strictest of its five water quality classes, allows a maximum BOD of 2 mg/L.
Previous Year Questions
UPSC 2017 asked what BOD is a standard criterion for.
- UPSC 2017The answer is pollution assay in aquatic ecosystems. BOD does not measure blood or air oxygen. View the question.
True or False: BOD is typically measured over 5 days of incubation at 20°C.
Why High BOD Kills Fish, and BOD vs COD
What BOD can and cannot tell you
- A high BOD suggests microbes can use much oxygen. Low dissolved oxygen can harm fish.
- Fish tolerance differs by species and life stage. Avoid one universal “safe” oxygen number.
- CPCB lists 4 mg/L or more for its fisheries class.
- Low BOD does not rule out toxic chemicals, disease-causing microbes or salt pollution.
- A sunny river can show high daytime DO despite organic waste. Measure both BOD and DO.
- Untreated sewage is a common source of organic loading. See the river biodiversity guide.
BOD and COD are different tests
| Question | BOD | COD |
|---|---|---|
| What acts? | Microorganisms | Chemical oxidant |
| Typical time | Five days | Hours |
| Best use | Biological oxygen demand | Chemically oxidisable load |
- COD is usually higher than five-day BOD in ordinary wastewater.
- “COD is always at least BOD” is too strong. The methods differ.
- Five-day BOD can include oxygen used during nitrification. Some methods block this to measure carbonaceous BOD.
- Do not treat the two numbers as interchangeable.
- Source: US EPA wastewater technical document.
Think it through: why can a river have low BOD but still be unsafe to drink?
BOD mainly warns about oxygen demand from biological decay. Harmful microbes or toxic substances need other tests. CPCB water-use classes require more than BOD.
True or False: Chemical Oxygen Demand (COD) is always at least as high as five-day Biological Oxygen Demand (BOD).
True or False: High BOD kills fish mainly by starving them of dissolved oxygen, not by direct poisoning.
True or False: A BOD result above 8 mg/L meets CPCB’s Class A limit for a drinking-water source.
Quick Q&A
What does BOD measure?
Oxygen microbes use on waste.
Standard test?
5 days at 20°C.
Class A BOD limit?
2 mg/L.
DO versus BOD?
DO is now. BOD is demand.
Is COD always higher?
No. Usually, not always.
🎲 Practice: Biological Oxygen Demand (BOD)
4 verified questions from this topic.
Question 1 of 1
Question 1 of 1
Question 1 of 1
Question 1 of 1